<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2 20190208//EN" "https://jats.nlm.nih.gov/publishing/1.2/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article" dtd-version="1.2" xml:lang="en">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">IJMABHR</journal-id>
<journal-title-group><journal-title>International Journal of Medical and All Body Health Research</journal-title><abbrev-journal-title>IJMABHR</abbrev-journal-title></journal-title-group>
<issn pub-type="epub">2582-8940</issn>
<publisher><publisher-name>Anfo Publication House</publisher-name></publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">415</article-id>
<article-id pub-id-type="doi">10.54660/IJMBHR.2025.6.4.137-150</article-id>
<title-group><article-title>Systematic Review: Development of Computed Tomography Technology to Reduce X-ray Exposure (2020-2025)</article-title></title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Saeed</surname><given-names>Rana Riyadh</given-names></name><xref ref-type="aff" rid="aff1"/></contrib>
<aff id="aff1"><label>1</label>Department of Radiology Techniques, Mosul Medical Technical Institute, Northern Technical University, Mosul, Iraq</aff>
</contrib-group>
<pub-date publication-format="electronic" date-type="pub"><day>15</day><month>12</month><year>2025</year></pub-date>
<volume>6</volume>
<issue>4</issue>
<fpage>137</fpage>
<lpage>150</lpage>
<history>
<date date-type="received"><day>05</day><month>10</month><year>2025</year></date>
<date date-type="accepted"><day>11</day><month>11</month><year>2025</year></date>
</history>
<permissions><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by-nc-sa/4.0/?utm"><license-p>CC BY-NC-SA 4.0</license-p></license></permissions>
<self-uri xlink:href="https://www.allmedicaljournal.com/article/415/systematic-review-development-of-computed-tomography-technology-to-reduce-x-ray-exposure-2020-2025"/>
<self-uri content-type="pdf" xlink:href="https://www.allmedicaljournal.com/article/415/download"/>
<abstract><p>Background: Radiation exposure from computed tomography (CT) remains a significant concern in medical imaging, prompting continuous technological innovation to optimize dose reduction while maintaining diagnostic image quality. This systematic review synthesizes recent developments in CT technology for radiation dose reduction from 2020 to 2025.

Objective: To systematically review and analyze technological advancements in CT imaging that reduce X-ray radiation exposure, evaluate their clinical effectiveness, and identify future research directions.

Methods: A comprehensive literature search was conducted across four major databases (SciSpace, PubMed, Google Scholar, and full-text repositories) for publications from January 2020 to November 2025. Search terms included combinations of “computed tomography,” “CT,” “radiation dose reduction,” “dose optimization,” “low dose,” and related technological terms. Studies were included if they reported on technological innovations for CT dose reduction with quantitative outcomes. A total of 99 unique papers were identified, combined, and reranked by relevance.

Results: Three primary technological tracks emerged: (1) Advanced reconstruction algorithms (iterative reconstruction and deep learning-based methods) achieving 36-89% dose reductions; (2) Photon-counting detector CT (PCCT) providing superior image quality at significantly lower doses compared to conventional energy-integrating detectors; (3) Optimized acquisition techniques including automatic exposure control, tube current modulation, and spectral shaping with tin filters achieving up to 89% dose reduction in specific protocols. Real-world clinical implementations demonstrated CTDIvol reductions up to 82% and DLP reductions up to 83.9% while maintaining or improving diagnostic accuracy.

Conclusions: Substantial progress has been made in CT dose reduction through convergent advances in reconstruction algorithms, detector hardware, and acquisition strategies. Deep learning reconstruction and photon-counting detectors represent paradigm shifts with proven clinical benefits. However, challenges remain in external validation, standardization across vendors, and task-specific optimization. Future research should focus on prospective multicenter trials, standardized benchmarking protocols, and integrated AI-driven dose optimization systems.</p></abstract>
<kwd-group kwd-group-type="author"><kwd>Computed tomography</kwd><kwd>radiation dose reduction</kwd><kwd>iterative reconstruction</kwd><kwd>deep learning</kwd><kwd>photon-counting detector</kwd><kwd>dose optimization</kwd><kwd>medical imaging technology</kwd></kwd-group>
</article-meta>
</front>
<back><ref-list><title>References</title>
<ref id="R1"><label>1</label><mixed-citation>Ungania S, Solivetti FM, D’Arienzo M, et al. Reducing radiation dose in computed tomography imaging of adolescent idiopathic scoliosis using spectral shaping technique with tin filter. Tomography. 2023;11(10):110. doi:10.3390/tomography11100110.</mixed-citation></ref>
<ref id="R2"><label>2</label><mixed-citation>Alagic Z. New developments in computed tomography: low dose techniques, image reconstruction, and spectral imaging. 2024. doi:10.69622/25975000.v1.</mixed-citation></ref>
<ref id="R3"><label>3</label><mixed-citation>Theek B, Nolte T, et al. Emerging methods in radiology. Radiologe. 2020;60(11). doi:10.1007/S00117-020-00696-0.</mixed-citation></ref>
<ref id="R4"><label>4</label><mixed-citation>Russo E, Stucchi E, Carlucci E, et al. Clinical implementation of AI for CT dose optimization and diagnostic reliability in oncology: a real-world evaluation. J Adv Health Care. 2025;7. doi:10.36017/jahc202574469.</mixed-citation></ref>
<ref id="R5"><label>5</label><mixed-citation>Kang Z, Li X, Zhou S. Recommendation of low-dose CT in the detection and management of COVID-2019. Eur Radiol. 2020;30. doi:10.1007/S00330-020-06809-6.</mixed-citation></ref>
<ref id="R6"><label>6</label><mixed-citation>Ng CKC. Artificial intelligence for radiation dose optimization in pediatric radiology: a systematic review. Children (Basel). 2022;9(7):1044. doi:10.3390/children9071044.</mixed-citation></ref>
<ref id="R7"><label>7</label><mixed-citation>Ungania S, Solivetti FM, D’Arienzo M, et al. New-generation ASiR-V for dose reduction while maintaining image quality in CT: a phantom study. Appl Sci. 2023;13(9):5639. doi:10.3390/app13095639.</mixed-citation></ref>
<ref id="R8"><label>8</label><mixed-citation>Woeltjen MM, Niehoff J, Michael AE, et al. Low-dose high-resolution photon-counting CT of the lung: radiation dose and image quality in the clinical routine. Diagnostics. 2022;12(6):1441. doi:10.3390/diagnostics12061441.</mixed-citation></ref>
<ref id="R9"><label>9</label><mixed-citation>Dieckmeyer M, Sollmann N, Kupfer K, et al. Computed tomography of the head. Clin Neuroradiol. 2023;33. doi:10.1007/s00062-023-01271-5.</mixed-citation></ref>
<ref id="R10"><label>10</label><mixed-citation>Adelodun MO, Anyanwu EC. Environmental and patient safety: advances in radiological techniques to reduce radiation exposure. Int J Front Med Surg Res. 2024;6(1). doi:10.53294/ijfmsr.2024.6.1.0040.</mixed-citation></ref>
<ref id="R11"><label>11</label><mixed-citation>Lin X, Zhuo W, Liu H, et al. Potential of fluid dynamic bowtie filter for dose reduction and image quality improvement of cone-beam CT. Appl Sci. 2022;12(18):9346. doi:10.3390/app12189346.</mixed-citation></ref>
<ref id="R12"><label>12</label><mixed-citation>Russo E, Stucchi E, Carlucci E, et al. Clinical implementation of AI for CT dose optimization and diagnostic reliability in oncology: a real-world evaluation. J Adv Health Care. 2025;7. doi:10.36017/jahc202574469.</mixed-citation></ref>