<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2 20190208//EN" "https://jats.nlm.nih.gov/publishing/1.2/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article" dtd-version="1.2" xml:lang="en">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">IJMABHR</journal-id>
<journal-title-group><journal-title>International Journal of Medical and All Body Health Research</journal-title><abbrev-journal-title>IJMABHR</abbrev-journal-title></journal-title-group>
<issn pub-type="epub">2582-8940</issn>
<publisher><publisher-name>Anfo Publication House</publisher-name></publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">134</article-id>
<article-id pub-id-type="doi">10.54660/Ijmabhr.2022.3.3.2</article-id>
<title-group><article-title>Time gain compensation in orbital ultrasonography</article-title></title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Khazaei</surname><given-names>Hadi M</given-names></name><xref ref-type="aff" rid="aff1"/></contrib>
<contrib contrib-type="author"><name><surname>Seethapathy</surname><given-names>G</given-names></name><xref ref-type="aff" rid="aff2"/></contrib>
<aff id="aff1"><label>1</label>Casey Eye Institute, Oregon Health &amp; Science University, Portland, Oregon, USA</aff>
<aff id="aff2"><label>2</label>Consultant Ophthalmic Plastic and Orbital Surgeon, Manipal Hospital, Salem, India</aff>
</contrib-group>
<pub-date publication-format="electronic" date-type="pub"><year>2022</year></pub-date>
<volume>3</volume>
<issue>3</issue>
<fpage>17</fpage>
<lpage>20</lpage>
<history>
<date date-type="received"><day>20</day><month>06</month><year>2021</year></date>
<date date-type="accepted"><day>05</day><month>07</month><year>2021</year></date>
</history>
<permissions><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by-nc-sa/4.0/?utm"><license-p>CC BY-NC-SA 4.0</license-p></license></permissions>
<self-uri xlink:href="https://www.allmedicaljournal.com/article/134/time-gain-compensation-in-orbital-ultrasonography"/>
<self-uri content-type="pdf" xlink:href="https://www.allmedicaljournal.com/article/134/download"/>
<abstract><p>Time gain compensation (TGC) is a setting applied in diagnostic ultrasound imaging to account for tissue attenuation. By increasing the received signal intensity with depth, the artifacts in the uniformity of a B-mode image intensity are reduced. The purpose of TGC is to normalize the signal amplitude with time, compensating for depth. rnWhen the image is displayed, similar materials should have similar brightness, regardless of depth; this is achieved by â€œLinear-in-dBâ€ Gain, which means the decibel gain is a linear function of the control voltage. Gain is expressed in dB, a logarithmic ratio of the output power relative to the input power. Gain can be calculated by subtracting the input from the output levels when both are expressed in dBm, which is power relative to 1 milliwatt.rnThe TGC creates uniformity in the brightness of the echoes when used in conjunction with the overall gain. The best approach is to center all the TGC settings before adjusting the overall gain. After adjusting the overall gain, the TGC can then be adjusted to compensate for attenuation at specific depth. Gain is a uniform amplification of the ultrasonic signal that returns to the transducer after it travels through the tissue.</p></abstract>
<kwd-group kwd-group-type="author"><kwd>Orbital Ultrasound</kwd><kwd>Time gain compensation (TGC)</kwd></kwd-group>
</article-meta>
</front>
<back><ref-list><title>References</title>
<ref id="R1"><label>1</label><mixed-citation>Garcia EM, Crowley J, Hagan C, Atkinson LL. Evolution of imaging in breast cancer. Clin. Obstet. Gynecol. 2016; 59:322-335.</mixed-citation></ref>
<ref id="R2"><label>2</label><mixed-citation>Hopp T, Gemmeke H, Ruiter NV, Tan WY, You W, Zapf M. Automated breast segmentation in ultrasound computer tomography SAFT images. In Proceedings of the SPIE Medical Imaging 2017, Orlando, FL, USA, 11-16 February 2017.</mixed-citation></ref>
<ref id="R3"><label>3</label><mixed-citation>Itoh A, Ueno E, Tohno E, Kamma H, Takahashi H, Shiina T, et al. Breast disease: Clinical application of US elastography. Radiology 2006, 239, 341–350.</mixed-citation></ref>
<ref id="R4"><label>4</label><mixed-citation>Paulus, D.D. Imaging in breast cancer. CA A Cancer J. Clin. 2010; 37:133-150.</mixed-citation></ref>
<ref id="R5"><label>5</label><mixed-citation>Cobbold RSC. Foundations of Biomedical Ultrasound; Oxford University Press: Oxford, UK, 2006.</mixed-citation></ref>
<ref id="R6"><label>6</label><mixed-citation>Bigelow TA, Labyed Y. Attenuation Compensation and Estimation. In Quantitative Ultrasound in Soft Tissues; Springer: Dordrecht, The Netherlands, 2013.</mixed-citation></ref>
<ref id="R7"><label>7</label><mixed-citation>Kim H, Varghese T. Hybrid spectral domain method for attenuation slope estimation. Ultrasound Med. Biol. 2008; 34:1808-1819.</mixed-citation></ref>
<ref id="R8"><label>8</label><mixed-citation>Lee D, Yong SK, Ra JB. Automatic time gain compensation and dynamic range control in ultrasound imaging systems. Proc. SPIE Int. Soc. Opt. Eng. 2006; 6147, 614708:1-614708:9.</mixed-citation></ref>
<ref id="R9"><label>9</label><mixed-citation>Hughes DI, Duck FA. Automatic attenuation compensation for ultrasonic imaging. Ultrasound Med. Biol. 1997; 23:651-664.</mixed-citation></ref>
<ref id="R10"><label>10</label><mixed-citation>P Sprawls. Physical Principles of Medical Imaging, Aspen, Rockville, Md, USA, 1987.</mixed-citation></ref>
<ref id="R11"><label>11</label><mixed-citation>JT Bushberg, JA Seibert, EM Leidholdt, JM Boone. The Essential Physics of Medical Imaging, Williams &amp; Wilkins, Philadelphia, Pa, USA, 2nd edition, 2002.</mixed-citation></ref>
<ref id="R12"><label>12</label><mixed-citation>L Silva. An Introduction to Ultrasound and the Body Metrix System, IntelaMetrix, Livermore, Calif, USA, 2010.</mixed-citation></ref>
<ref id="R13"><label>13</label><mixed-citation>JP Noce. Fundamentals of diagnostic ultrasonography, Biomedical Instrumentation and Technology. 1990; 24(6):456-459.</mixed-citation></ref>
<ref id="R14"><label>14</label><mixed-citation>Byrne SF. Standardized echography of the eye and orbit. Neuroradiology. 1986; 28(5-6):618-640.</mixed-citation></ref>
<ref id="R15"><label>15</label><mixed-citation>Ossoinig KC. The role of standardized echography in Graves’ disease. Acta Ophthalmol Suppl. 1992; 204:81.</mixed-citation></ref>
<ref id="R16"><label>16</label><mixed-citation>Hasenfratz G. Orbital tumours-the importance of standardized echography. Acta Ophthalmol Suppl. 1992; 204:82-86.</mixed-citation></ref>
<ref id="R17"><label>17</label><mixed-citation>Werner SC, Coleman DJ, Franzen LA. Ultrasonographic evidence of a consistent orbital involvement in Graves’ disease. New Engl J Med. 1974; 290(26):1447-1450.</mixed-citation></ref>
<ref id="R18"><label>18</label><mixed-citation>Willinsky RA, Arenson AAM, Hurwitz JJ, Szalai J. Ultrasonic B-scan measurement of the extraocular muscles in Graves’ orbitopathy. J Can Assoc Radiol. 1984; 35(2):171-173.</mixed-citation></ref>
<ref id="R19"><label>19</label><mixed-citation>Khazaei H, Khazaei D, Ashraf D, Mikkilineni S, Ng JD. Overview of Orbital Ultrasonography. Ann Ophthalmol Vis Sci. 2022; 5(1):1028.</mixed-citation></ref>
<ref id="R20"><label>20</label><mixed-citation>Khazaei H, Khazaei D, Brundage D, Mikkilineni S, International Journal of Medical and All Body Health Research www.allmedicaljournal.com Dailey RA. Facial Ultrasonography in acquired facial lipoatrophy. Inter J. Research and Scientific Innovation (IJRSI). 2021; 9:48-51.</mixed-citation></ref>
<ref id="R21"><label>21</label><mixed-citation>Khazaei H, Khazaei D, Ashraf D, Mikkilineni S, Ng JD. Ultrasonographic Characteristics of the Facial Nerve in Patient with Bell’s Palsy. Ann Ophthalmol Vis Sci. 2022; 5(1):1029.</mixed-citation></ref>
<ref id="R22"><label>22</label><mixed-citation>Li X, Liu DC. Estimation of local attenuation and its application to rationalized gain control. In Proceedings of the 2007 1st International Conference on Bioinformatics and Biomedical Engineering (ICBBE 2007), Wuhan, China, 6-8 July, 2007.</mixed-citation></ref>
</ref-list></back>
</article>